ProductShow:index > Product
 
Product name: Z [Technical data sheet ]
[The outlook and installs the size ]
Characteristic and use:

This series motor used polygon structure so that the using rate of the stator’s inner space is vary high.The magnet yoke is laminated style,suitable for silicon controlled commutate power supply,and it can edure pulsating current and rapid change of current (load change).Magnetic poles are fixed by precise orientation.All the motors of system are with compensate winding,so the reverse performance is very well. The insulation class of the motor is F,using of reliable insulation structure and nonmenstruum vacuum pressure impregnated,guaranteeing the stable performance of insulation and good heat dissipation.

Electrical machinery performance:  
 1.Data listed in the technical data sheet should be employed under the following conditions:
a)Altitude above sea level maximal1,000m;
b)Cooling air temperature maximal40℃;COOling water temperature maximal32℃;
c)The motor can be installed under foul situation,but the right cooling method of cooling method of cooling and defend class must be chosen. If the situation is special,need humid tropic,please negotiate.
d)The motor is suitable for 3-phase bridge style comoothing reactor, also can adopt power supply of DC generator.
e)The motor accord with GB755《The ration and performance of the rotating electrical machinery》、IEC60034-1 《The ration and performance of the rotating electricel machinery》and JB/T9577《Technical requirements of series Zmiddle motor electromotor》;
2.The standrd rated voltage of the electromotor are 440V、550V、660V、 750V etc.Voltage of other classes can also be derived according specific situation,but must be negotiated when ordering.
3.The basic excitation style is separately excited,the excited voltage is 220V,Voltage of other classes can also be derived according specific situation,but must be negotiated when ordering.
4.short time overload capacity of motor.
Motor can be divided into two kinds according to the use
Frist kind (A):ordinary industrial DC motor;Second kind(B):metal rolling mill DC motor.
a)First kind(A)motor can endure the overload(1min)according to table 3
table 3

基速的百分比

额定电流的百分比

percentage of basic speed

percentage of basic speed

偶尔使用

经常使用

seldon using

constantly using

100

200

175

200

160

150

300以上

140

125


b)First kind (B)motor can endure the overload(1min)according to table 4
table 4

基速的百分比

额定电流的百分比

percentage of basic speed

percentage of basic speed

偶尔使用

经常使用

seldon using

constantly using

100

200(180*)

175(160*)

200

160(180*)

160

300以上

175(160*)

140

*:当电动机的基速等于大于650r/min时,用括号内数值。
*When the basic speed of the motor650r/minusing the number in the bracket.

c)The short time overload capacity seldom used means happens infrequency or only at the urgency,the motor working exceed the continuous rated overload capacity,we suggest you adjust the instantaneous open/close decice of the switch according to the short time overload capacity seldom using.
The short time overload capacity seldom constantly used means it's an part of the normal working period,the motor endure the continuous rated overload capacity again and again.After working at shor time overload,it must working light load to make the overload period's overload root-mean-square less than its continuous ration.
d)Second kind DC motor(B)can endure the following continuous load; Working continuous within the rated voltage and rotate speed with 115% rated power overload,the temperature is higher when at this overload, other features maybe different from working at the rated condition.
Within the rated voltage and rotate speed,after running at the rated overload, working at the 125% rated power for two hours,the temperature rise can't overrun the regulated numerical value other features maybe different from working at the rated condition.
e)Second kind DC motor(B),at the rated rotate speed,the overload can reach 2.5 times no longer than 15s only used once in a while.
5.The change rate of current
Under all rotate speed and load,the change rate of current(di/dt)that the motor can endure is 250 times rated current.
6.Libration and noise
a)The libration of the motor accords with GB10068《Measurement evaluation and limits of the vibration severity of rotating electrical machines which the shaft center height is 56mm and above》center standard's regulation.
b)The noise of the motor accords with GB10069.3《Measurement of airborne noise emitted by rotating electrcal machinery and noise limits》.
7.The efficiencies listed in the data sheet are for rated output, voltage and speed,and include excitation loss.

The chice of the motors'capacity
1.First kind(A):Ordinary industrial DC motor The technical data of this kind of motor please see the technical data table. The buyer can decide the capacity、voltage、running speed and the method of cooling of the motor at the buyer's optin.
2.Second kind(B):Metal rolling mill DC motor The output power of this kind of motor is about 20% lower than kind(A),the detail numerical value can be negotiated by the user and the manufacture.
3.Exclude the specification of technical data in the table,manufacturer can derive other specification at the requirement of the user.

Model explanation:  
 
Structure synopsis:  

1.The methods and defend class of the motor
a)The method of cooling of the motor is separately-cooled,according to the GB/T1993《Method of cooling of rotating electrical machinery》,there are IC06、IC17、IC37、IC86W. Standard entrance of cooling air is at the end of the main transmission(not the commutator side).The defend class of the motor can be divided into IP23 and IP44 according to the GB/T4942.1《the crust defend class of rotating edectrical machinery(IP code)》. If the user needs other method of cooling and defend class, it can be negotiated.
b)The relation between the method of cooling and the defend class of the motor please see Table 1
table 1

c)The cooling wind、wind pressure、cooling water flux、motor power see Table 2.
table 2

机座

骑式鼓风机

/水冷却器

Frame

built-on blower

air-to-water heat exchanger

冷却风量

风压(静压)

电动机功率*

重量

冷却水流量

电动机功率*

重量

cooling wind

wind pressure (whisht pressure)

motor power

wight

cooling water flux

motor power

wight

m3/hr

Pa

kW

kg

m3/hr

kW

kg

H500

10000

1900

7.5

300

19

11

900

H560

16500

2250

15

400

22

18.5

1100

H710

23500

2400

18.5

600

40

2×11

1600

2.The installation and the type of motor according to the GB/T997 《The structure and installation type of rotating electrical machinery》, haveIM1001(horizontal borrom install、column uniaxia)and IM1002(horizontal bottom install、column biaxial). If the user needs other kinds of installation structure, it must be negotiated.
3.The position of terminal bos on standard motor is on the right side when seeing from the main drive end. It can also be installed on the left side, but it must be written in the order contact.
4.The motor using rolling bearing,nonstop adding oil structure.
5.The motor can be installed the following accessories at the user's option
a)Temperature detector component can be put into the stator winding and bearing room of two side,and connect the outlet wire to the terminal box.
b)The non-drive part of the machine can equipped with tachogenerator、centrifugal starting switch、coder and others which buildup the speed meter protecting device.
c)Heater for preventing condensation can be installed in the motor, but it must be written in the other contact.
6.The air-to-water heat exchanger is usually installed on the top of the motor.If the user want it to be insralled on the side of the motor,theuser must put forward it when ordering and settle the assistant upholder by the user himself.
7.The cooler equipped with wind pressure switch、temperature controller、heater for preventing condensation and other protect device.

Content:  
1.The motor type, power,voltage,running speed,excitation type,cooling style,number of output draft, position of outlet box, etc must be written when ordering.
2.Please give clear indication of the accessory’s type、specification and number installed on the motor when ordering.
3.If the environment of using is special, humid torrid zone type motor is needed please write “H”after the original type.
4.If you have some special requirement of the specification and technical requirement which is not listed in the booklet,please contact us. Please make it clear and negotiate with the related department and sign the contract or trial-produce agreement after the acknowledgement.